MICRO HF-E CHARGER

Features :

  • Single Phase Input Voltage 230 V 15%.
  • Suitable for lead acid / gel batteries.
  • IUIa recharge profile, with equalising and maintenance charge.
  • Microprocessor controlled.
  • LED's indicating state of charge and fault condition.
  • Suitable for wall fixing.
  • Robust metal case.
  • Cooling by forced ventilation.
  • Reverse polarity protection.
  • Overall charge timer protection.
  • Incorrect battery voltage protection.
  • Over heat protection.
  • Automatic operation.
   
   
BATTERY CHARGER RPM2 - RTM2

Features :

  • WA charging mode, in compliance with curve DIN 41774.
  • Automatic start after an 8 second delay.
  • Pre-charging mode (1h); detection system ensuring - prevention of overcharging.
  • Desulphating charge.
  • Proportional gassing.
  • Pulsed equalising mode.
  • Maintenance charge.
  • Microprocessor controlled and multi-voltage pc board.
  • Charging progress display
   
   
BATTERY CHARGER MICRO SW33

Features :

  • Three Phase Input Voltage 400 V ±15 %.
  • Suitable for lead acid / gel batteries.
  • IUIa recharge profile, with equalising and maintenance charge.
  • Microprocessor control and switch mode operation.
  • Selectable recharge profile.
  • LED's indicating state of charge.
  • LCD display indicating state of charge and fault condition.
  • Suitable for wall fixing.
  • Robust metal construction.
  • Forced air-cooling.
  • Reverse polarity protection.
  • Overall charge timer protection.
  • Incorrect battery voltage protection.
  • Over heat protection.
  • Automatic operation.
  • DC safe connect.
   
   
BATTERY CHARGER MICRO SW2"
   

Features :

  • IUIa recharge profile (or WUIa).
  • Suitable for wet/gel batteries.
  • Metal caseLED's flashing to particular pattern to indicate fault conditions and charger status.
  • Fan ventilation
 

MICRO SW2 to suit Lead Acid batteries

TYPE

Iout stage I1 (A)

VPC stage U (V)

Iout stage I2

(A)

VPC compensation (V)

Max power

(kW)

24/20

20

2,40

5

2,10 ÷ 2,25

0,70

24/25

25

2,40

6

2,10 ÷ 2,25

0,90

24/30

30

2,40

7,5

2,10 ÷ 2,25

1,05

24/35

35

2,40

8,5

2,10 ÷ 2,25

1,15

24/40

40

2,40

10

2,10 ÷ 2,25

1,35

36/15

15

2,40

3,8

2,10 ÷ 2,25

0,80

36/20

20

2,40

5

2,10 ÷ 2,25

1,05

 

MICRO SW2 to suit gel batteries

TYPE

Iout stage I1 (A)

VPC stage U (V)

Iout stage I2

(A)

VPC compensation (V)

Max power

(kW)

24/20

20

2,30

2

2,10 ÷ 2,25

0,69

24/25

25

2,30

2,5

2,10 ÷ 2,25

0,85

24/30

30

2,30

3

2,10 ÷ 2,25

1,00

24/35

35

2,30

3,5

2,10 ÷ 2,25

1,15

24/40

40

2,30

4

2,10 ÷ 2,25

1,30

36/15

15

2,30

1,5

2,10 ÷ 2,25

0,75

36/20

20

2,30

2

2,10 ÷ 2,25

1,00